Fleck 5800 Control Valve
Fleck's electromechanical timers are simple to program and easy to service. The robust electromechanical powerhead is designed with heavy-duty 3/8" wide plastic gears and a simple mechanical design for quick access to all internal components.
Classification:
Consumables and equipment
Control Valves
Fleck Control Valves
Keywords:
Protec Arisawa Pressure Vessels
DESCRIPTION
- DESCRIPTION
- INTRODUCTION
- CASE
-
Product Description:
At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 2510, 5800, 5600, 7000, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 different options and over 1,000 configurations.
Fleck 5800
The Fleck 5800 XTR2 commercial valve with a 3/4" to 1-1/4" NPT, BSP, and sweat. With a 1.05 inch distributor pilot. Typically, the 2510 valve is used on 6 inch diameter to 16 inch diameter pressure vessels. The valve has a Cv of 5.4 GPM and can backwash up to 17 GPM. The weight of just the valve is approximately 10 pounds with a working pressure range of 20 to 125 psi. Operating temperatures range from 34 degrees to 110 degrees Fahrenheit. When the 2510 valve is used for a water softener application a 1610 brine valve is used.How to Order Fleck Valve?
•Specify the valve needed is for back wash filter or water softener.
•Specify the flow rate needed for your application
•Specify the size of tank being used when ordering to ensure proper flow restrictor sizing.
•Fleck valve has different option, please discuss your application with Pure Aqua representative to offer the best options to fit your application.Models:
Valve Specifications
Valve material
Inlet/Outlet
Cycles
Fiber-reinforced polymer
3/4" to 1-1/4" NPT, BSP, and sweat
5
Flow Rates (50 psi Inlet) - Valve Alone
Continuous (15 psi drop)
Peak (25 psi drop)
Cv (flow at 1 psi drop)
Max. backwash (25 psi drop)
21 GPM
27 GPM
5.4
17 GPM
Regeneration
Downflow/Upflow
Adjustable cycles
Time available
Both
Brine fill only
LXT: minutes calculated
SXT: 0-199 minutes per cycle
XTR2: 0-240 minutes per cycleMeter Information
Meter accuracy
Meter Capacity Range
3/4" Paddle/Turbine:
LXT:
SXT:
XTR2:
0.25 - 15 GPM ± 5%
(0.06 - 3 m³/h)Volume Calculated
1 - 999,900 gal
(0 - 3,785 m³1,000 - 9,900,000 gal
(3.8 - 37,476 m³ )Dimensions
Distributor pilot
Drain line
Injector brine system
Brine line
Mounting base
Height from top of tank
1.05" O.D.
1/2" NPTF
1610 - 3/8"
3/8"
2.5" - 8 NPSM
9"
Additional Information
Electrical rating
Max. VA
Estimated shipping weight
Pressure
Temperature
24 v, 110 v, 220 v - 50 Hz, 60 Hz
72
Time Clock: 19 lbs
Metered Valve: 27 lbsHydrostatic: 300 psi (20 bar)
Working: 20 - 125 psi (1.4 - 8.5 bar)Cold Water Valve: 34 - 110°F (1 - 43°C)
Typical Applications
Water softener
Iron Filter
Water softener
Iron Filter
Iron Filter
6" - 16" diameter
8" - 16" diameter
8" - 16" diameter
8" - 16" diameter
8" - 16" diameter
* As defined in the U.S. EPA Safe Drinking Water Act; the product also meets California Proposition 65 Standards
Features:
Model 5800 XTR2 3/4" to 1-1/4" Commercial Control Valve
•Time of day super capacitor backup for power loss
•Large color LCD touch screen display
•Programmable relay output
•Remote lockout and regeneration input
•Easy electronic programming
•Error alarm
•Assistance screen with dealer contact information
•Programmable assistance interval with alarm for service
•Master settings by category
•Intuitive nativation
•Field Programmer for quick configuration and diagnostic data download to PC via USB
•Password lockout screen for added security
•Vacation mode to save water when not in useDIAGNOSTICS
•Current Flow Rate
•Peak Flow Rate (can be reset)
•Totalizer (can be reset)
•Last Regeneration
•Daily usage for last four weeks
•Reserve
•Software Version
•Number of Regenerations
•Regeneration Interval
•Usage since last regeneration
•Last program changeOptions:
•Filter or softener control valves
•Downflow co-current or upflow counter-current regeneration
•Plumbing connections in 3/4" to 1-1/4" NPT, BSP, and sweat
•Fiber-reinforced polymer or stainless steel bypass valve
•Variable reserve for increased efficiency
•Programmable regeneration types for increased flexibility
•Three color bezel options of black, silver, or blue
•XTR2- Premium touch screen LCD display with two programmable relay outputs for both normally opened and normally closed contacts
•SXT-Large LCD display and user-selectable time clock or metered function; usable for filtration and softener systems
•LXT- Midsize LCD display comes preprogrammed for your choices of softener or filter and time clock or metered, with a maximum of 5 parameters to complete set-upApplications:
•Commercial softeners
•Commercial Media Filters
•Commercial Carbon Filters
•Commercial Iron Removal FiltersDocs:
Fleck 5800XTR2 Spec Sheet
Fleck 5800XTR2 Service ManualVideos:
Reviews:
☆☆☆☆☆ (1 review) Write a Review
☆☆☆☆☆
Better priced...
Posted by Osvaldo B. on Jan 21st 2016Better priced over closest competition. Quality is also very good
INTRODUCTION
CASE
Previous Page : Aquafine SL Series
Next page : Fleck 2750 Control Valve
Project
Related products
Codeline 80U Membrane Housings
The CodeLine 80U Fiberglass RO Pressure Vessel is designed for continuous, long term use as a housing for reverse osmosis membrane elements to desalt typical brackish waters at pressures up to 600 psi. Any make of eight-inch nominal diameter spiral-wound element is easily accommodated; the appropriate interfacing hardware for the element specified is furnished with the vessel.
View MoreCodeline 160E Membrane Housings
CodeLine™ is working with some of the world leaders in the membrane industry to make 16” Technology a possibility. 16” Membrane Housings can accommodate four times higher flow rates when compared to the standard 8” vessels.
View MoreCodeline 160S Membrane Housings
CodeLine™ is working with some of the world leaders in the membrane industry to make 16” Technology a possibility. 16” Membrane Housings can accommodate four times higher flow rates when compared to the standard 8” vessels.
View More