HYDRAsub MAX HSMM1600-ES Membrane

HYDRAsub MAX HSMM1600-ES Membrane was engineered and patented with a special diffuser system for controlled aeration built into the stainless steel enclosure. These new applications are ideal for processes regarding the treatment of wastewater, along with many other uses.

Classification:

Consumables and equipment

Membrane Bioreactor Modules

Hydranautics Membrane Bioreactor Modules

Keywords:

Disinfection Products

HYDRAsub MAX HSMM1600-ES Membrane
HYDRAsub MAX HSMM1600-ES Membrane
HYDRAsub MAX HSMM1600-ES Membrane
HYDRAsub MAX HSMM1600-ES Membrane
+
  • HYDRAsub MAX HSMM1600-ES Membrane
  • HYDRAsub MAX HSMM1600-ES Membrane
  • HYDRAsub MAX HSMM1600-ES Membrane
  • HYDRAsub MAX HSMM1600-ES Membrane

DESCRIPTION

  • DESCRIPTION
  • INTRODUCTION
  • CASE
  • Product Description:

    HYDRAsub MAX HSMM1600-ES Membrane was engineered and patented with a special diffuser system for controlled aeration built into the stainless steel enclosure. These new applications are ideal for processes regarding the treatment of wastewater, along with many other uses.

     

    Models:

     

    HYDRAsub®MAX- MBR

    HSMM1600-ES





    Module
    Specifications

    Configuration:
    Fiber Orientation:
    Filtrate Flow:
    Membrane Polymer:
    Pore Size (nominal):
    Number of Elements in Module:
    Nominal Membrane Area per Module:
    Permeate Connections:
    Air Connections:
    Guide Pipe Connections:
    Typical Module Dry Weight:
    Typical Module Wet Weight:

    Submerged Membrane
    Vertical
    Bi-directional
    Polyvinylidene Flouride (PVDF)
    0.5 μm
    40 (40 m² each)
    17,216 ft2 (1600 m²)
    (2)- 3” MNPT
    (2)- 3” MNPT
    (2)- To fit 3” pipe
    2460 lbs (1118 kg)
    4226 lbs (1916 kg)


    Typical
    Process
    Conditions

    Operating Filtrate Flux:
    Peak Operating Flux:
    Chemically Enhanced Backwash (CEB) Flux:
    CEB Chemicals:
    Clean In Place (CIP) Flux:
    CIP Chemicals:

    4-20 gfd (7-34 lmh)
    30 gfd (51 lmh)
    2.4 gfd (4 lmh)
    NaOCld
    2.4 gfd (4 lmh)
    NaOCl or Citric Acidd

     

    Features:

    •Maximum Trans Membrane Pressure (Vacuum): -6 psig (-0.41 bar)
    •Maximum Backwash Trans Membrane Pressure: 2 psig (0.14 bar)
    •Maximum Instantaneous Chlorine Concentration: 5,000 ppma
    •Maximum Chlorine Tolerance: 742,000 ppm-hrsb
    •MLSS Range: 8,000 - 12,000 mg/Lc
    •Operating Temperature Range: 41 - 104°F (5 - 40° C)
    •Feed Water pH Range: 6.0 - 8.0
    •Cleaning pH Range: 1.0 - 11.0
    •Operating Mode: Outside to Inside

     

    Applications:

    •HYDRAsub MAX HSMM1600-ES Membrane utilzies cutting-edge features to improve the performance of municipal and industrial wastewater applications, including chemical, textile, food and beverage, palm oil applications, etc.

     

    Docs:

    HYDRAsub MAX HSMM1600-ES Membrane Data Sheet

     

    Videos:

     

     

    Reviews:

    ☆☆☆☆☆ (1 review) Write a Review

    ☆☆☆☆☆

    Fast shipping
    Posted by Paco M. on Apr 10th 2020

    Loved them!

INTRODUCTION

CASE

Project


Related products


Fleck 2750 Control Valve

Fleck's electromechanical timers are simple to program and easy to service. The robust electromechanical powerhead is designed with heavy-duty 3/8" wide plastic gears and a simple mechanical design for quick access to all internal components.

View More

Fleck Electromechanical Timers

Fleck's electromechanical timers are simple to program and easy to service. The robust electromechanical powerhead is designed with heavy-duty 3/8" wide plastic gears and a simple mechanical design for quick access to all internal components.

View More

Clack WS1TC Control Valve

Clack's WS1 Automatic valve is a state-of-the-art control head designed for residential and commercial applications requiring flow rates up to 27 GPM (6.1 m³/hr). It has a backwash abilitiy capable of servicing up to 22" diameter tanks.

View More

< 1234 >

Product consultation


I want more details. Delivery Time Payment Method Delivery Channel