DOW FILMTEC SFD-2660 Ultrafiltration Modules

DOW FILMTEC ECO elements offer unparalleled rejection and flow performance for your industrial water needs, enabling lower energy usage and reduced regeneration costs in downstream polishing units. With a new industry-leading performance of 99.7 percent rejection at 150 psi, DOW ECO elements provide robust performance over a longer element life. At highest quality, the elements deliver 40 percent lower salt passage at 30 percent less energy, when compared to standard RO elements - an ecological and economic win.

Classification:

Consumables and equipment

Membranes

Dupont Filmtec Membranes

Keywords:

DOW FILMTEC SFD-2660 Ultrafiltration Modules
DOW FILMTEC SFD-2660 Ultrafiltration Modules
DOW FILMTEC SFD-2660 Ultrafiltration Modules
DOW FILMTEC SFD-2660 Ultrafiltration Modules
DOW FILMTEC SFD-2660 Ultrafiltration Modules
+
  • DOW FILMTEC SFD-2660 Ultrafiltration Modules
  • DOW FILMTEC SFD-2660 Ultrafiltration Modules
  • DOW FILMTEC SFD-2660 Ultrafiltration Modules
  • DOW FILMTEC SFD-2660 Ultrafiltration Modules
  • DOW FILMTEC SFD-2660 Ultrafiltration Modules

DESCRIPTION

  • DESCRIPTION
  • INTRODUCTION
  • CASE
  • Product Description:

    The SFD series of the DOW ultrafiltration modules are especially suitable for drinking water applications. They are built with robust outside-in PVDF fiber technology. The hollow fibers feature high clean-ability, low chemical consumption, high recovery, and a superior combination of mechanical properties and chemical resistance.

    DOW ultrafiltration SFD-2660 is an ideal choice for small systems and allows a compact design. They are certified under NSF/ANSI Standard 61 for safe use in drinking water applications.

    Advantages
    • Excellent removal of colloids, particles, and bacteria
    • Low chemical consumption
    • Ability to treat challenging feed water with limited pretreatment
    • High chemical-tolerant PVDF that allows aggressive chemical use for treating challenging water when needed
    • Mechanically strong fibers enabling long module life

    Important Information
    Proper start-up of a UF system is essential to prepare the membranes for operating service and to prevent membrane damage. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved. Before initiating system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration and other system checks should be completed. Please refer to the product technical manual.

    Operation Guidelines
    Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. Flush the UF system to remove shipping solution prior to start up. Remove residual air from the system prior to start up. Manually start the equipment. Target a permeate flow of 60% of design during initial operations. Depending on the application, permeate obtained from initial operations should be discarded. Please refer to the product technical manual.

    General Information

    If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty (Form No. 795-00027) will be null and void.
    To prevent biological growth during system shutdowns, it is recommended that preservative solution be injected into the membrane modules.

     

    Models:

    Specification

    Model

    Type

    Part Number

    Membrane Area

    Module Volume

    Weight (empty/water filled)

    m2

    f2

    liters

    gallons

    kg

    lbs

    SFD-2660

    NSF/ANSI 61 Drinking Water

    324166

    33

    355

    16

    4.2

    25/41

    55/90

     

    Features:

    The DOW™ ultrafiltration (UF) modules are made from high strength, hollow fiber membranes that have excellent features and benefits:

    •0.03 µm nominal pore diameter for removal of bacteria, viruses, and particulates including colloids to protect downstream processes such as RO
    •PVDF polymeric hollow fibers for high strength and chemical resistance allows longer membrane life
    •Hydrophilic PVDF fibers for easy cleaning and wettability that help maintain long term performance
    •Outside In flow configuration for high tolerance to feed solids that helps reduce the need for pretreatment processes
    •U-PVC housing, helping to eliminate the need for costly pressure vessels 

    Operating Parameters

     

    SI Units

    US Units

    Filtrate Flux @ 25°C

    40 - 120 l/m2/hr

    24 - 70 gfd

    Flow Range

    1.3–4.0 m3/hr

    5.9–17.3 gpm

    pH, Operating

    2-11

    Temperature

    1 - 40°C

    34 - 104°F

    Max. Inlet Module Pressure (@ 20°C)

    6.25 bar

    93.75 psi

    Max. Operating TMP

    2.1 bar

    30 psi

    Max. Operating Air Scour Flow

    12 Nm3/hr

    7.1 scfm

    Max. Backwash Pressure

    2.5 bar

    36 psi

    NaOCl (max)

    2,000 mg/L

    TSS (max)

    100 mg/L

    Turbidity (max)

    300 ntu

    Particle Size (max)

    300 μm

    Flow Configuration

    Outside In, Dead End Flow

    Expected Filtrate Turbidity

    ≤ 0.1 NTU

    Expected Filtrate SDI

    ≤ 2.5

     

    Applications:

    •Ground water and surface water treatment
    •Seawater desalination pretreatment
    •Waste water treatment
    •Municipal drinking water systems
    •Containerized systems

     

    Docs:

    DOW FILMTEC SFD-2660 Membrane

     

     

    Videos:

     

     

    Reviews:

    ☆☆☆☆☆ (1 review) Write a Review

    ☆☆☆☆☆

    Best material
    Posted by Nilza L. on Jan 22nd 2020

    VERY FAST DELIVERY, THANKS

INTRODUCTION

CASE

Project


Related products


DOW FILMTEC NF270-2540 Membrane

The DOW FILMTEC NF270 membrane elements are ideal for removing a high percentage of TOC and THM precursors with medium to high salt passage and medium hardness passage. The DOW FILMTEC NF270 membrane is an ideal choice for surface water and ground water where good organic removal is desired with partial softening.

View More

DOW FILMTEC ECO-400i Membrane

DOW FILMTEC ECO elements offer unparalleled rejection and flow performance for your industrial water needs, enabling lower energy usage and reduced regeneration costs in downstream polishing units. With a new industry-leading performance of 99.7 percent rejection at 150 psi, DOW ECO elements provide robust performance over a longer element life. At highest quality, the elements deliver 40 percent lower salt passage at 30 percent less energy, when compared to standard RO elements - an ecological and economic win.

View More

< 1 >

Product consultation


I want more details. Delivery Time Payment Method Delivery Channel
submit